Construction Specifications for Detached Private Garage
Name of Property Owner: _______________________________________________________
Address of Proposed Structure: ___________________________________________________
Permanent Index Number: _______________________________________________________
Contractor: ___________________________________________________________________
A CURRENT PLAT OF SURVEY SHOWING EXISTING STRUCTURES AND PROPOSED
GARAGE LOCATION MUST BE SUBMITTED WITH GARAGE PERMIT APPLICATION.
Size of Structure: ______ FT. X ______ FT. Style of Roof:
____Hip ____Gable ____Flat
Distance from Dwelling: ______ FT. Distance from Side Lot Line:
______ FT.
Overhang: _______ inches
Note: No detached accessory building or structure
located in a required rear yard shall exceed the
height of the principal building or structure. However, in no case shall such
accessory building or
structure exceed seventeen (17) feet in height.
Fill
Under the floor, there will be four (4) inches of sand or crushed stone.
Foundation
The four outer edges will be a minimum of ten (10) inches deep, four (4)
inches below existing grade
and six (6) inches above grade. The trench will be twenty (20) inches wide at the
bottom.
Floor
The floor will be concrete, five (5) inches thick.
The floor and foundation will be will be poured
monolithic. 6 X 6, #10 wire mesh--protected concrete to be five (5) bag mix; exposed
concrete,
six (6) bag mix.
Anchors
There will be 1/2 X 8 inch machine bolts placed in the concrete at
intervals of eight (8) feet., and
not more than twelve (12) inches from each other..
Sills
There will be single 2 X _____'s laid full-length around the slab.
Wall Studs
There will be 2 X _____'s placed on _____-inch centers.
Top Plates
There will be two 2 X _____'s on Edge: _____ Flat: _____
Siding
The exterior siding will be _______________________________________
Roof Rafters
The roof rafters will be 2 X _____'s on _____-inch centers
Rafter Ties
There will be three (3) 2" X 6" rafter ties (gable roof)
Roof Sheathing
The roof sheathing will be plywood.
Roofing
The roofing material will be 235-lb. Seal-Tab shingles.
Bracing in Single Wall
The walls will be sway-braced at the four corners. Braces to be
mortised into the top and bottom
plates and not less than two (2) studs.
Jambs & Headers
There will be double jambs and headers at all openings. There will be
a double 2X header over the
auto door with a steel plate.
Electric
There will be ceiling lights, outside lights, convenience outlets.
The wiring from the house to the
garage will be in conduit trench all wiring in the garage will be in conduit, #12
wire. The garage
will not be tied into the house circuit that is now in use. All electricity going
into the garage will
be fused separately.
The applicant hereby agrees that the proposed structure will be built in accordance
with the building
code of the Village of Hazel Crest.
Applicant's Signature:_________________________________ Date Submitted:
______________
Approved By: _______________________________________ Date Approved:
______________
Rev. 6/23/85 |